| Public Class CCoolingOD
 | |
|     Public Overridable Sub Calc_CoolingSystem(ByVal i_count_month As Integer, ByVal theta_e As Decimal)
 | |
| 
 | |
|         Dim T As String = "냉방기기"
 | |
|         Dim c_p1 As Decimal, c_p2 As Decimal, c_cl As Decimal
 | |
|         Dim b As Decimal, L As Decimal, n_G As Decimal, h_G As Decimal, L_max As Decimal, R As Decimal, z As Decimal
 | |
|         Dim rho_cl As Decimal
 | |
|         Dim eta_c_star_d As Decimal, eta_c_star_ce_sens As Decimal, eta_c_star_ce As Decimal, eta_c_d As Decimal, eta_c_ce As Decimal, eta_c_ce_sens As Decimal
 | |
|         Dim Q_c_star_s As Decimal, Q_c_s As Decimal, Q_c_b As Decimal, Q_vc_b As Decimal, Q_vm_b As Decimal, Q_c_b_i As Decimal, Q_c_star_b_i As Decimal
 | |
|         Dim Q_c_star_b As Decimal, Q_m_star_b As Decimal, Q_c_star_d As Decimal, Q_c_star_ce As Decimal, Q_c_d As Decimal, Q_c_ce As Decimal
 | |
|         Dim Q_c_star_outg As Decimal, Q_z_outg_l As Decimal, Q_m_star_outg As Decimal, Q_dot_c_outg As Decimal, Q_c_outg As Decimal, Q_c_outg_total As Decimal, Q_dot_z As Decimal
 | |
|         Dim Q_c_ce_aux As Decimal, Q_z_aux_d_l As Decimal, Q_z_star_outg_l As Decimal
 | |
|         Dim f_c_ce_aux As Decimal, f_Abgl As Decimal, f_e As Decimal
 | |
|         Dim V_dot_z As Decimal
 | |
|         Dim EER As Decimal, PLV_av As Decimal
 | |
|         Dim P_d_hydr As Decimal, P_Pump As Decimal
 | |
|         Dim beta_d_l As Decimal, e_d_l As Decimal
 | |
|         Dim W_d_hydr_l As Decimal
 | |
|         Dim Q_c_f_elektr As Decimal, Q_c_f_R_elektr As Decimal, Q_dot_R_outg As Decimal, Q_c_outg_therm As Decimal, Q_c_f As Decimal, Q_c_aux As Decimal
 | |
|         Dim t_h_max As Integer
 | |
|         Dim Q_c_g As Decimal, Q_c_g_v_i As Decimal, Q_dot_N As Decimal, Q_dot_d_in As Decimal
 | |
|         Dim theta_VA As Decimal, theta_RA As Decimal, theta_HK_m_beta_h_d As Decimal, beta_h As Decimal, n_beta As Decimal
 | |
|         Dim eta_k_100 As Decimal, eta_k_pl As Decimal, f As Decimal, e As Decimal, q_B_70 As Decimal, q_B_theta As Decimal, f_Hs_Hi As Decimal
 | |
|         Dim Q_V_g_100 As Decimal, Q_dot_B_h As Decimal, Q_V_g_pl As Decimal, q_R_elektr As Decimal
 | |
|         Dim beta_k_pl As Decimal, Delta_theta_z_cl As Decimal
 | |
|         Dim Delta_P_WUE As Decimal, Delta_P_WUV As Decimal, Delta_P_RV As Decimal, Delta_p_z As Decimal
 | |
|         Dim k_n As Decimal, f_1_av As Decimal, f_2_av As Decimal, f_R_av As Decimal, T_W_1_i As Decimal, l_min_i As Decimal
 | |
|         Dim use_Oil As Decimal, use_LNG As Decimal, use_LPG As Decimal, use_Elec As Decimal, use_DH As Decimal
 | |
| 
 | |
|         '20100223 제거 i_count_chiller As Integer, 최적화중 사용안함
 | |
|         'Dim i_count_zone As Integer, i_count_c_d As Integer
 | |
|         Dim i_count_beta As Integer, k_n_index As Integer
 | |
|         ' Dim i_count_renewable As Integer
 | |
|         Dim i_HeatCool As Integer
 | |
|         Dim theta_i As Decimal, Q_hp_outg As Decimal, Q_c_f_hp As Decimal, Q_c_g_hp_aux As Decimal
 | |
|         Dim Q_chp_outg As Decimal, Q_c_f_chp As Decimal
 | |
|         Dim system_type As Integer
 | |
|         '==================================2010.2.21 수정
 | |
|         Dim use_DC As Decimal
 | |
|         Dim d_op_mth As Integer
 | |
|         Dim d_op_max_mth As Integer
 | |
|         ' Dim i_count_profile As Integer
 | |
|         use_DC = 0
 | |
|         d_op_max_mth = 0
 | |
|         '==================================2010.2.21 수정
 | |
|         '==================================2010.04.02 수정
 | |
|         Dim Q_H_sol_out_m As Decimal, Q_W_sol_out_m As Decimal, W_sol_aux_m As Decimal
 | |
|         Dim Q_h_outg_i As Decimal
 | |
| 
 | |
|         Q_H_sol_out_m = 0
 | |
|         Q_h_outg_i = 0
 | |
|         '==================================2010.04.02 수정
 | |
| 
 | |
| 
 | |
| 
 | |
|         eta_c_star_d = 0.95 '건물 내 배관 적용
 | |
|         eta_c_star_ce_sens = 1 '습도요구 편차없음 적용
 | |
|         eta_c_star_ce = 0.9 '공조기기로 냉열전달에서 현열전달효율로 우선 0.9 적용
 | |
|         Q_c_star_s = 0
 | |
|         Q_c_s = 0 '(3.2.8-22)
 | |
|         eta_c_d = 0.9 ' 우선 적용 추후 검토
 | |
|         eta_c_ce = 1  ' 우선 적용 추후 검토
 | |
|         eta_c_ce_sens = 0.9 '우선 적용 추후 검토
 | |
|         f_c_ce_aux = 0.04 ' 표3.93 우선 적용 추후 검토
 | |
|         f_Abgl = 1 '수리역학적으로 평형을 이룬 배관망
 | |
|         Q_c_f = 0
 | |
|         Q_c_aux = 0
 | |
|         beta_k_pl = 0.3
 | |
|         PLV_av = 1
 | |
|         use_Oil = 0
 | |
|         use_LNG = 0
 | |
|         use_LPG = 0
 | |
|         use_Elec = 0
 | |
|         use_DH = 0
 | |
|         i_HeatCool = 2
 | |
|         system_type = 2
 | |
| 
 | |
| 
 | |
|         Dim 냉동기용량합 As Decimal = 0
 | |
|         For Each dr냉방 As DS.tbl_nangbangkikiRow In DSET1.tbl_nangbangkiki.Select("code<>'0'", "code")
 | |
|             If IsNumeric(dr냉방.냉동기용량) Then 냉동기용량합 += (dr냉방.냉동기용량 * TOSG(T, dr냉방.대수))
 | |
|         Next
 | |
| 
 | |
|         Dim Mon As String = "M" & Format(i_count_month, "00")
 | |
|         For Each dr냉방 As DS.tbl_nangbangkikiRow In DSET1.tbl_nangbangkiki.Select("code<>'0'", "code")
 | |
| 
 | |
|             'log.debug(String.format("cool title=%s", drCooling.getCode()));
 | |
|             ' Console.WriteLine(String.Format("cool title={0}", dr냉방.code))
 | |
| 
 | |
|             '//이 냉방기가가 존에서 사용되었는지확인한다.
 | |
|             Dim Drow존() As DS.tbl_zoneRow = CType(DSET1.tbl_zone.Select("code <> '0'"), DS.tbl_zoneRow())
 | |
|             If Drow존.GetUpperBound(0) <> -1 Then ' Worksheets("냉방기기").Range("냉방생산기기1").Offset(2, i_count_chiller - 1) = "0001" Then '2
 | |
|                 Q_c_b = 0
 | |
|                 Q_c_star_b = 0
 | |
|                 t_h_max = 0
 | |
|                 Q_c_f_elektr = 0
 | |
|                 Q_c_outg_therm = 0
 | |
|                 Q_c_g = 0
 | |
|                 Q_c_f_R_elektr = 0
 | |
| 
 | |
| 
 | |
|                 For Each Dr존 As DS.tbl_zoneRow In DSET1.tbl_zone.Select("code <> '0'", "code")
 | |
|                     'Console.WriteLine(String.Format("냉방기기={0},존={1},mon={2}", dr냉방.설명, Dr존.code, i_count_month))
 | |
| 
 | |
|                     Dim Drow분석() As DSR.월별에너지분석Row = CType(DSETR1.월별에너지분석.Select("월='" & Mon & "' and 존='" & Dr존.code & "'"), DSR.월별에너지분석Row())
 | |
|                     ' 존데이터를가져올떄 해당 냉방기기에서 사용한 존만 가져왔따.
 | |
|                     ' If Dr존.열생산냉방생산기기 <> "" Then ' Worksheets("입력존").Range("입력냉방생산기기1").Offset(0, i_count_zone - 1) <> "" Then
 | |
|                     ' If Dr존.열생산냉방생산기기 = dr냉방.code Then ' Worksheets("입력존").Range("입력냉방생산기기1").Offset(0, i_count_zone - 1) = Worksheets("냉방기기").Range("냉방생산기기1").Offset(0, i_count_chiller - 1) Then
 | |
| 
 | |
|                     If (Dr존.냉난방방식 = "냉난방" OrElse Dr존.냉난방방식 = "냉방") Then
 | |
|                         Q_c_b_i = Result1o.E분석(i_count_month).냉방에너지요구량열(Dr존.code) * (TOSG(T, dr냉방.냉동기용량) * TOSG(T, dr냉방.대수)) / 냉동기용량합 ' CSng(Drow분석(0).냉방요구량열) ' Sheets("" & i_count_month & "").Cells(10, 7 + i_count_zone)
 | |
|                         Q_c_b = Q_c_b + Q_c_b_i
 | |
|                     End If
 | |
|                     If Dr존.냉난방공조 = "냉난방" OrElse Dr존.냉난방공조 = "냉방" OrElse ((Dr존.냉난방공조 = "환기" OrElse Dr존.냉난방공조 = "난방") And Dr존.외기부하처리여부 = "예") Then
 | |
|                         'If (Dr존.냉난방공조 = "환기" OrElse Dr존.냉난방공조 = "난방") And Dr존.외기부하처리여부 = "예" Then '// 2010.11.19 추가
 | |
|                         Q_c_star_b_i = TOSG(T, Drow분석(0).냉방요구량공조) * TOSG(T, dr냉방.냉동기용량) * TOSG(T, dr냉방.대수) / 냉동기용량합  '//2010.11.19 추가
 | |
|                         'Else
 | |
|                         'Q_c_star_b_i = Result1o.E분석(i_count_month).공조에너지요구량냉방(Dr존.code) * TOSG(T,dr냉방.냉동기용량) / 냉동기용량합 ' CSng(Drow분석(0).공조요구량냉방) ' Sheets("" & i_count_month & "").Cells(21, 7 + i_count_zone)
 | |
| 
 | |
|                         ' End If
 | |
| 
 | |
|                         Q_c_star_b = Q_c_star_b + Q_c_star_b_i
 | |
|                     End If
 | |
| 
 | |
|                     '===================================================================================2010.2.21 수정
 | |
|                     Dim Dr프로필 As DS.tbl_profile_odRow = CType(DSET1.tbl_profile_od.Select("code='0'")(0), DS.tbl_profile_odRow)
 | |
|                     Dim Drow최대() As DSR.최대냉난방부하Row = CType(DSETR1.최대냉난방부하.Select("zone='" & Dr존.code & "'"), DSR.최대냉난방부하Row())
 | |
| 
 | |
|                     If i_count_month = 0 Then
 | |
|                         d_op_mth = 0
 | |
|                     Else
 | |
|                         d_op_mth = CInt(Dr프로필("day" & Format(i_count_month, "00")))
 | |
|                     End If
 | |
| 
 | |
|                     If t_h_max < TOSG(T, Drow최대(0).난방최대가동시간) * d_op_mth Then
 | |
|                         t_h_max = CInt(TOSG(T, Drow최대(0).난방최대가동시간) * d_op_mth)
 | |
|                     End If
 | |
|                     If d_op_max_mth < d_op_mth Then
 | |
|                         d_op_max_mth = d_op_mth
 | |
|                     End If
 | |
|                     '===================================================================================2010.2.21 수정
 | |
|                     ' End If
 | |
|                     ' End If
 | |
|                 Next
 | |
| 
 | |
|                 'Q_vh_b = Sheets("" & i_count_month & "").Cells(19, 7 + i_count_zone)
 | |
|                 'Q_vc_b = Sheets("" & i_count_month & "").Cells(21, 7 + i_count_zone)
 | |
|                 'Q_vm_b = Sheets("" & i_count_month & "").Cells(23, 7 + i_count_zone)
 | |
| 
 | |
| 
 | |
|                 '==========================================================================================================================================
 | |
|                 ' 가열유닛에 대한 사용에너지(3차 에너지)
 | |
|                 ' 외부 공조덕트가 없어서 Q_vh_d 는 0으로 적용
 | |
| 
 | |
|                 'Q_dot_V_H_max = V_dot_star_rho_L(c_p_L * (theta_ZUL_wi - theta_AUL_wi) - Delta_h_WRG) '(3.2.5-58)
 | |
|                 'Q_dot_V_H_max = V_dot_star * rho_L(h_ZUL_wi - h_AUL_wi - Delta_h_WRG) '(3.2.5-57)
 | |
|                 'b_VH_a = sigma1_12(b_VH_month) '(3.2.8-7)
 | |
|                 'b_VH_mth = Q_vh_b / Q_dot_V_H_max '(3.2.8-6)
 | |
|                 't_H_r = t_H_r_14_12h + (t_H_r_22_12h - t_H_r_14_12h) * (theta_V_mech - 14) / 8 '(3-B.1) theta_V_mech은 (3-C.1)
 | |
|                 't_H_star_op_mth = t_H_r * b_VH_mth / b_VH_a '(3.2.8-5)
 | |
|                 'Q_vh_d = f_vh_d * A_K_A * t_H_star_opo_mth '(3.2.8-10) f_vh_d=16W/m
 | |
| 
 | |
|                 'Q_vh_ce = (1 - eta_vh_ce) * Q_vh_b '(3.2.8-9) eta_vh_ce 는 1로 Q_vh_ce 는 0이 됨
 | |
|                 'Q_h_star_b = Q_vh_b 'Q_h_star_b = Q_vh_b + Q_vh_ce + Q_vh_d '(3.2.8-2)
 | |
|                 '==========================================================================================================================================
 | |
| 
 | |
| 
 | |
| 
 | |
|                 '==========================================================================================================================================
 | |
|                 ' 냉각 유닛에 대한 사용 에너지(3차 에너지)
 | |
|                 ' 외부 공조덕트가 없어서 Q_vc_d 는 0으로 적용
 | |
| 
 | |
|                 'Q_dot_V_C_max = V_dot_star * rho_L(h_AUL_so - h_ZUL_so - Delta_h_WRG) '(3.2.5-62)
 | |
|                 'b_VC_a = sigma1_12(b_VC_month) '(3.2.8-13)
 | |
|                 'b_VC_mth = Q_vc_b / Q_dot_V_C_max '(3.2.8-12)
 | |
|                 't_C_r = (t_C_r_14_12h + (t_C_r_22_12h - t_C_r_14_12h) * (theta_V_mech - 14) / 8) * f_h_C '(3-B.2) theta_V_mech은 (3-C.1)
 | |
|                 't_C_star_op_mth = t_C_r * b_VC_mth / b_VC_a '(3.2.8-11)
 | |
|                 'Q_vc_d = f_vc_d * A_K_A * t_C_star_opo_mth '(3.2.8-10) f_vh_d=9W/m
 | |
|                 'Q_vc_ce = (1 - eta_vc_ce) * Q_vc_b '(3.2.8-9) eta_vc_ce 는 1로 Q_vc_ce 는 0이 됨
 | |
| 
 | |
|                 'Q_c_star_b = Q_vc_b 'Q_c_star_b = Q_vc_b + Q_vc_ce + Q_vc_d '(3.2.8-8)
 | |
| 
 | |
|                 '==========================================================================================================================================
 | |
| 
 | |
| 
 | |
|                 '가습
 | |
|                 Q_m_star_b = Q_vm_b '(3.2.8-14)
 | |
| 
 | |
| 
 | |
|                 ' 실-냉방 냉열 공급
 | |
| 
 | |
|                 'Q_c_b = Sheets("" & i_count_month & "").Cells(7, 7 + i_count_zone)
 | |
| 
 | |
|                 Q_c_d = (1 - eta_c_d) * Q_c_b '(3.2.8-21) eta_c_d는 (Tab.7-8)
 | |
|                 Q_c_ce = ((1 - eta_c_ce) + (1 - eta_c_ce_sens)) * Q_c_b '(3.2.5-20) eta_c_ce는(Tab.7-8), eta_c_ce_sens는 (Tab.7-7)
 | |
| 
 | |
|                 Q_c_outg = Q_c_b + Q_c_ce + Q_c_d + Q_c_s '(3.2.8-19)
 | |
| 
 | |
| 
 | |
| 
 | |
|                 '==========================================================================================================================================
 | |
|                 ' 실-냉방 2차 공기 송풍기의 전기에너지 요구량
 | |
|                 ' 추후 세부 변수 검토
 | |
| 
 | |
|                 'beta_c_i = beat_c_we = Q_c_b_we / (Q_c_max_res * t_c_op_we) '(2-D.7)
 | |
|                 'beta_c_i = beta_c_nutz = Q_c_b_nutz / (Q_c_max_res * t_c_op_nutz)
 | |
|                 't_c_i = t_mth_nutz = d_nutz * t_c_op_nutz '(2-D.8) t_c_i=t_mth_we=d_we*t_c_op_we
 | |
|                 't_c_i = t_mth_i * beta_c_i / beta_c_grenz '(2-D.6)
 | |
|                 't_c_op = t_c_NR + t_c_we '(2-D.5)
 | |
|                 'Q_c_outg = Q_c_b + Q_c_ce + Q_c_d + Q_c_s '(3.2.8-19)
 | |
|                 'Q_c_ce_aux = f_c_ce_aux * Q_c_outg * t_c_op / 1000 '(3.2.8-23) f_c_ce_aux 는 (Tab.3.93)
 | |
|                 Q_c_ce_aux = f_c_ce_aux * Q_c_outg * t_h_max / 1000
 | |
| 
 | |
| 
 | |
|                 '==========================================================================================================================================
 | |
| 
 | |
| 
 | |
| 
 | |
| 
 | |
|                 '공조-냉방 냉열 공급
 | |
| 
 | |
|                 Q_c_star_d = (1 - eta_c_star_d) * Q_c_star_b '(3.2.8-18) eta_c_star_d는 (Tab.3.91)
 | |
|                 Q_c_star_ce = ((1 - eta_c_star_ce) + (1 - eta_c_star_ce_sens)) * Q_c_star_b '(3.2.8-16) eta_c_star_ce는 (Tab.3.91), eta_c_star_ce_sens는 (Tab.3.91)
 | |
| 
 | |
|                 Q_c_star_outg = Q_c_star_b + Q_c_star_ce + Q_c_star_d + Q_c_star_s '(3.2.8-15)
 | |
|                 Q_z_star_outg_l = Q_c_star_outg
 | |
| 
 | |
| 
 | |
|                 ' 공조기기 가습에 필요한 생산기의 이용열 교부
 | |
| 
 | |
| 
 | |
|                 'Q_m_star_d = 0
 | |
|                 'Q_m_star_ce = 0
 | |
|                 'Q_m_star_b = Q_vm_b '(3.2.8-14)
 | |
|                 Q_m_star_outg = Q_m_star_b 'Q_m_star_outg = Q_m_star_b + Q_m_star_ce + Q_m_star_d '(3.2.8-24)
 | |
| 
 | |
| 
 | |
|                 Q_c_outg_total = Q_c_outg + Q_c_star_outg
 | |
| 
 | |
|                 Q_z_outg_l = Q_c_outg_total
 | |
| 
 | |
| 
 | |
| 
 | |
|                 '==================================================================================================================================
 | |
|                 '==================================================================================================================================
 | |
|                 '지열시스템
 | |
| 
 | |
|                 Dim CRenew As New CRenewableOD
 | |
|                 If dr냉방.연결된시스템.Trim <> "" AndAlso dr냉방.연결된시스템 <> "0" AndAlso dr냉방.연결된시스템 <> "(없음)" Then ' 시스템연결" Then
 | |
|                     Dim Dr신재생 As DS.tbl_newRow = CType(DSET1.tbl_new.Select("code='" & dr냉방.연결된시스템 & "' and code <> '0'")(0), DS.tbl_newRow)
 | |
|                     '//연결되었을시에는 
 | |
|                     Select Case Dr신재생.기기종류.Trim
 | |
|                         Case "태양열" '//태양열
 | |
|                         Case "태양광" '//태양광
 | |
|                         Case "지열" '//지열
 | |
|                             Select Case Dr신재생.가동연료.Trim
 | |
|                                 Case "전기" '전기"
 | |
|                                     CRenew.Calc_HeatpumpSystem(system_type, i_HeatCool, Dr신재생, Q_c_outg_total, i_count_month, d_op_max_mth, t_h_max, theta_VA, theta_i, Q_hp_outg, Q_c_f_hp, Q_c_g_hp_aux)
 | |
|                                     Q_c_outg_total = Q_c_outg_total - Q_hp_outg
 | |
|                                     Q_c_f = Q_c_f + Q_c_f_hp + Q_c_g_hp_aux
 | |
|                                     use_Elec = use_Elec + Q_c_f_hp + Q_c_g_hp_aux
 | |
|                                 Case "천연가스" '천연가스"
 | |
|                                     CRenew.Calc_HeatpumpSystem(system_type, i_HeatCool, Dr신재생, Q_c_outg_total, i_count_month, d_op_max_mth, t_h_max, theta_VA, theta_i, Q_hp_outg, Q_c_f_hp, Q_c_g_hp_aux)
 | |
|                                     Q_c_outg_total = Q_c_outg_total - Q_hp_outg
 | |
|                                     Q_c_f = Q_c_f + Q_c_f_hp + Q_c_g_hp_aux
 | |
|                                     use_LNG = use_LNG + Q_c_f_hp
 | |
|                                     use_Elec = use_Elec + Q_c_g_hp_aux
 | |
|                                 Case "액화가스" '액화가스"
 | |
|                                     CRenew.Calc_HeatpumpSystem(system_type, i_HeatCool, Dr신재생, Q_c_outg_total, i_count_month, d_op_max_mth, t_h_max, theta_VA, theta_i, Q_hp_outg, Q_c_f_hp, Q_c_g_hp_aux)
 | |
|                                     Q_c_outg_total = Q_c_outg_total - Q_hp_outg
 | |
|                                     Q_c_f = Q_c_f + Q_c_f_hp + Q_c_g_hp_aux
 | |
|                                     use_LPG = use_LPG + Q_c_f_hp
 | |
|                                     use_Elec = use_Elec + Q_c_g_hp_aux
 | |
|                             End Select
 | |
|                         Case "열병합" '//열병합
 | |
|                            
 | |
|                     End Select
 | |
|                 End If
 | |
| 
 | |
|                 '==================================================================================================================================
 | |
|                 '==================================================================================================================================
 | |
| 
 | |
|                 EER = TOSG(T, dr냉방.열성능비) ' Dr냉방.열성능비
 | |
|                 Q_dot_c_outg = TOSG(T, dr냉방.냉동기용량) * TOSG(T, dr냉방.대수)  ' dr냉방.냉동기용량
 | |
| 
 | |
|                 If (Q_dot_c_outg * t_h_max) = 0 Then
 | |
|                     k_n = 0 '//170515
 | |
|                 Else
 | |
|                     k_n = Q_c_outg_total / (Q_dot_c_outg * t_h_max)
 | |
|                 End If
 | |
| 
 | |
| 
 | |
|                 If k_n > 1 Then k_n = 1
 | |
| 
 | |
|                 k_n_index = 100 ' 조건에 없는 압축방식에서 에러 발생 유도함
 | |
| 
 | |
|                 Select Case dr냉방.냉동기방식 'Dr냉방.냉동기방식
 | |
|                     Case "압축식", "압축식(LNG)" '압축식"
 | |
|                         T_W_1_i = 32
 | |
|                         Select Case dr냉방.냉동기종류 ' Dr냉방.냉동기종류
 | |
| 
 | |
|                             Case "수냉식" '수냉식"
 | |
|                                 k_n_index = 7
 | |
|                                 f_2_av = 1
 | |
| 
 | |
| 
 | |
|                             Case "공냉식" '공냉식"
 | |
|                                 k_n_index = 4
 | |
|                                 f_2_av = 1
 | |
| 
 | |
|                             Case "히트펌프"
 | |
|                                 k_n_index = 4
 | |
|                                 f_2_av = 1
 | |
| 
 | |
| 
 | |
|                         End Select
 | |
|                         '//이부분정확히 살펴보아야할듯 
 | |
|                         If k_n = 0 Then k_n = 0.001 ' 부분부하율이 0일 경우 부분부하를 0에서 0.1구간으로 설정
 | |
|                         'Dim Drow부분부하() As DS.tbl_buhaRow = DSET1.tbl_buha.Rows(k_n_index) '.Select("code='" & Format(9 - Int((1 - k_n) * 10), "00") & "'")
 | |
| 
 | |
|                         If k_n_index >= 100 Then
 | |
|                             Log.AppendLine("냉방기기(" & dr냉방.설명 & ")의 냉동기방식(" & dr냉방.냉동기방식.Trim & ")에따른 종류를 확인할 수 없습니다")
 | |
|                             Exit For 'Return
 | |
|                         Else
 | |
|                             f_1_av = TOSG(T, DSET1.tbl_buha.Rows(k_n_index)(CInt(9 - Int((1 - k_n) * 10) + 2))) ' Worksheets("부분부하율").Range("냉동기부분부하율1").Offset(k_n_index, 9 - Int((1 - k_n) * 10))
 | |
|                         End If
 | |
| 
 | |
|                         PLV_av = f_1_av * f_2_av
 | |
|                         If dr냉방.냉동기방식 = "압축식" Then
 | |
|                             Q_c_f_elektr = Q_c_outg_total / (EER * PLV_av)
 | |
|                             '======================================================================= 2010.10.5 추가
 | |
|                         ElseIf dr냉방.냉동기방식 = "압축식(LNG)" Then
 | |
|                             Q_c_outg_therm = Q_c_outg_total / (EER * PLV_av)
 | |
|                             use_LNG = use_LNG + Q_c_outg_therm
 | |
|                             '======================================================================= 2010.10.5 추가
 | |
|                         End If
 | |
|                         If (dr냉방.냉동기방식 = "압축식" Or dr냉방.냉동기방식 = "압축식(LNG)") And dr냉방.냉동기종류 = "수냉식" Then 'If Dr냉방.냉동기방식 = "압축식" And Dr냉방.냉동기종류 = "수냉식" Then
 | |
|                             Q_dot_R_outg = Q_dot_c_outg * (1 + 1 / EER)
 | |
|                             l_min_i = TOSG(T, 1.2103 - 0.0162 * (theta_e - 5)) '건구온도에서 -5도로 습구온도 설정 20180901
 | |
|                             'f_R_av = (Log(1 - 0.5 / 0.8) * l_min_i / (Log(1 - 0.5 / 0.8) * 0.87)) ^ 2 ' 냉각탑 가동시간을 부분부하 25%이상이면 가동하는 것으로 계산 추후 수정
 | |
|                             f_R_av = Q_c_outg_total * 4 / (Q_dot_c_outg * t_h_max) ' 냉각탑 가동시간을 부분부하 25%이상이면 가동하는 것으로 계산 추후 수정
 | |
|                             If f_R_av > 1 Then f_R_av = 1 ' 냉각탑 가동시간을 부분부하 25%이상이면 가동하는 것으로 계산하고 최대가동시간 이하로 계산 추후 수정
 | |
| 
 | |
| 
 | |
|                             '//170627 2348
 | |
|                             Select Case dr냉방.증발식건식냉각기.Trim
 | |
|                                 Case "증발식(개방형)"
 | |
|                                     q_R_elektr = 0.018
 | |
|                                 Case "증발식(폐쇄형)"
 | |
|                                     q_R_elektr = 0.033
 | |
|                                 Case "건식"
 | |
|                                     q_R_elektr = 0.045
 | |
|                             End Select
 | |
| 
 | |
| 
 | |
|                             Q_c_f_R_elektr = Q_dot_R_outg * q_R_elektr * f_R_av * t_h_max
 | |
|                         Else
 | |
|                             Q_c_f_R_elektr = 0
 | |
|                         End If
 | |
| 
 | |
| 
 | |
|                     Case "흡수식" '흡수식"
 | |
|                         Q_dot_R_outg = Q_dot_c_outg * (1 + 1 / EER)
 | |
|                         T_W_1_i = 32
 | |
|                         l_min_i = TOSG(T, 1.2103 - 0.0162 * (theta_e - 5)) '건구온도에서 -5도로 습구온도 설정 20180901
 | |
|                         'f_R_av = (Log(1 - 0.5 / 0.8) * l_min_i / (Log(1 - 0.5 / 0.8) * 0.87)) ^ 2 ' 냉각탑 가동시간을 부분부하 25%이상이면 가동하는 것으로 계산 추후 수정
 | |
| 
 | |
|                         If (Q_dot_c_outg * t_h_max) = 0 Then
 | |
|                             f_R_av = 0 '//170515
 | |
|                         Else
 | |
|                             f_R_av = Q_c_outg_total * 4 / (Q_dot_c_outg * t_h_max) ' 냉각탑 가동시간을 부분부하 25%이상이면 가동하는 것으로 계산 추후 수정
 | |
|                         End If
 | |
| 
 | |
|                         If f_R_av > 1 Then f_R_av = 1 ' 냉각탑 가동시간을 부분부하 25%이상이면 가동하는 것으로 계산하고 최대가동시간 이하로 계산 추후 수정
 | |
| 
 | |
|                         '//170627 2348
 | |
|                         Select Case dr냉방.증발식건식냉각기.Trim
 | |
|                             Case "증발식(개방형)"
 | |
|                                 q_R_elektr = 0.018
 | |
|                             Case "증발식(폐쇄형)"
 | |
|                                 q_R_elektr = 0.033
 | |
|                             Case "건식"
 | |
|                                 q_R_elektr = 0.045
 | |
|                         End Select
 | |
|                         'q_R_elektr = 0.018
 | |
| 
 | |
|                         Q_c_f_R_elektr = Q_dot_R_outg * q_R_elektr * f_R_av * t_h_max
 | |
| 
 | |
|                         f_2_av = TOSG(T, 1.7174 - 0.0217 * T_W_1_i)
 | |
| 
 | |
|                         '//13번째줄
 | |
|                         If k_n = 0 Then k_n = 0.01 ' 부분부하율이 0일 경우 부분부하를 0에서 0.1구간으로 설정
 | |
|                         f_1_av = TOSG(T, DSET1.tbl_buha.Rows(13)(CInt(9 - Int((1 - k_n) * 10) + 2))) 'Worksheets("부분부하율").Range("냉동기부분부하율1").Offset(13, 9 - Int((1 - k_n) * 10))
 | |
|                         PLV_av = f_1_av * f_2_av
 | |
| 
 | |
| 
 | |
| 
 | |
|                         Q_c_outg_therm = Q_c_outg_total / (EER * PLV_av)
 | |
| 
 | |
| 
 | |
|                         Select Case dr냉방.사용연료.ToString
 | |
|                             Case "난방유"
 | |
|                                 use_Oil = use_Oil + Q_c_outg_therm
 | |
|                             Case "천연가스"
 | |
|                                 use_LNG = use_LNG + Q_c_outg_therm
 | |
|                             Case "액화가스"
 | |
|                                 use_LPG = use_LPG + Q_c_outg_therm
 | |
|                             Case "지역난방" '지역난방"
 | |
|                                 use_DH = use_DH + Q_c_outg_therm
 | |
| 
 | |
|                             Case Else
 | |
|                                 MsgBox("냉동기기(" & dr냉방.설명 & ")가 직화식이나 사용연료가 없습니다.확인바랍니다.", vbOKOnly, "총량 에너지 평가 프로그램(ECO_Lite)")
 | |
|                         End Select
 | |
| 
 | |
| 
 | |
| 
 | |
|                     Case "지역냉방" '지역냉방"
 | |
|                         '--------------------------------------------------------------------------------------------------2010.02.22 수정
 | |
|                         use_DC = use_DC + Q_c_outg_total
 | |
|                         '--------------------------------------------------------------------------------------------------2010.02.22 수정
 | |
|                         Q_c_outg_therm = Q_c_outg_total
 | |
| 
 | |
|                 End Select
 | |
| 
 | |
|                 Q_c_f = Q_c_f + Q_c_f_elektr + Q_c_f_R_elektr + Q_c_outg_therm + Q_c_g
 | |
|                 use_Elec = use_Elec + Q_c_f_elektr + Q_c_f_R_elektr
 | |
| 
 | |
|                 'Console.WriteLine(String.Format("=>coolin mon={0}, gcf={1}, elect={2}", i_count_month, Q_c_f, use_Elec))
 | |
|                 'log.debug(String.format("=>coolin mon=%s, gcf=%s, elect=%s", i_count_month, Q_c_f,use_Elec));
 | |
| 
 | |
|                 '// 냉수, 냉각수 분배
 | |
|                 Q_dot_z = Q_dot_c_outg * (1 + 1 / EER) '(3.2.8-30)
 | |
|                 P_d_hydr = 1
 | |
| 
 | |
|                 If dr냉방.냉동기종류 = "히트펌프" Then '//170627 2355
 | |
|                     P_Pump = (TOSG(T, dr냉방.냉수펌프동력)) * 1000 'Worksheets("냉방분배시스템").Range("급수온도1").Offset(9, i_count_c_d - 1)
 | |
|                 Else
 | |
|                     P_Pump = (TOSG(T, dr냉방.냉수펌프동력) + TOSG(T, dr냉방.냉각수펌프동력)) * 1000 'Worksheets("냉방분배시스템").Range("급수온도1").Offset(9, i_count_c_d - 1)
 | |
|                 End If
 | |
| 
 | |
| 
 | |
| 
 | |
|                 f_e = P_Pump / P_d_hydr '원래는 P_hydr '(3.2.8-37)
 | |
|                 c_p1 = 0.75
 | |
|                 c_p2 = 0.25
 | |
|                 If Q_z_outg_l <> 0 Then
 | |
|                     If (Q_dot_z * t_h_max) = 0 Then
 | |
|                         beta_d_l = 0 '//170515
 | |
|                     Else
 | |
|                         beta_d_l = Q_z_outg_l / (Q_dot_z * t_h_max) '(3.2.8-34) t_d_l 을 t_h_max으로 사용
 | |
|                     End If
 | |
| 
 | |
|                     If beta_d_l = 0 Then
 | |
|                         e_d_l = 0
 | |
|                     Else
 | |
|                         e_d_l = f_e * (c_p1 + c_p2 / beta_d_l) '(3.2.8-36)
 | |
|                     End If
 | |
| 
 | |
| 
 | |
|                     W_d_hydr_l = P_d_hydr / 1000 * t_h_max * beta_d_l * f_Abgl '(3.2.8-27)  t_d_l 을 t_h_max으로 사용
 | |
| 
 | |
|                     Q_z_aux_d_l = W_d_hydr_l * e_d_l '(3.2.8-26)
 | |
|                     'Q_z_aux_d_a = sigma(Q_z_zux_d_l) '(3.2.8-25)
 | |
| 
 | |
|                     Q_c_aux = Q_c_aux + Q_z_aux_d_l
 | |
|                 End If
 | |
| 
 | |
| 
 | |
| 
 | |
|                 'Console.WriteLine("loop 2")
 | |
| 
 | |
|             End If '2
 | |
|             'Console.WriteLine("loop 1")
 | |
|         Next '1
 | |
| 
 | |
| 
 | |
| 
 | |
|         '//계산결과 시트의 각 월에해당되는 곳에 데이터를 기록한다.
 | |
| 
 | |
|         Result1o.E소요량(i_count_month).냉방 = Q_c_f
 | |
|         Result1o.E소요량(i_count_month).냉방보조 = Q_c_aux
 | |
| 
 | |
|         use_Elec = use_Elec + Q_c_aux
 | |
| 
 | |
|         Result1o.일차E소요량(i_count_month).냉방등유 = use_Oil
 | |
|         Result1o.일차E소요량(i_count_month).냉방LNG = use_LNG
 | |
|         Result1o.일차E소요량(i_count_month).냉방LPG = use_LPG
 | |
|         Result1o.일차E소요량(i_count_month).냉방지역난방열 = use_DH
 | |
|         '--------------------------------------------------------------------------------------------------2010.02.22 수정
 | |
|         Result1o.일차E소요량(i_count_month).냉방지역냉방열 = use_DC
 | |
|         '--------------------------------------------------------------------------------------------------2010.02.22 수정
 | |
|         Result1o.일차E소요량(i_count_month).냉방전력 = use_Elec
 | |
| 
 | |
|     End Sub
 | |
| End Class
 | 